A three-phase AC voltmeter is an electrical instrument used to measure the voltage in a three-phase alternating current (AC) system. It is specifically designed to measure the voltage across the three-phase lines in a balanced or unbalanced three-phase system.
In a three-phase AC system, there are three conductors or phases, labelled as phase A, B, and C. These phases are ideally separated by 120 degrees from each other. The Voltage Meter 3 phase is connected across any two of these phases or between a phase and the neutral conductor, depending on the type of system.
The voltmeter measures the voltage between these two points and provides the reading in volts. It helps in determining the magnitude of voltage in a three-phase AC system, which is essential for analysing and monitoring the system's performance.
Yokins Instruments Private Limited proudly stands as the leading Manufacturers and traders of top-quality Three Phase Voltmeter. With our commitment to precision and excellence, we have established ourselves as the go-to choice in the industry.
Furthermore, our dedicated customer support team strives to cater to your specific requirements and provide expert guidance throughout your purchasing process. With Yokins Instruments Private Limited, you can trust that you are getting the best Three Phase AC Voltmeters that are built to last. Choose us as your reliable Manufacturers for all your voltage measurement needs.
Display | 4 Digit Red LED Super Bright Display |
Digit Height | 0.56"/14.2.mm |
Maximum display | 9999 (Max.) Counts |
Resolution | 0.001 to 1 Count Depending on Range/ Scale Display |
Display Stability | With in ±1 Digit |
Faceplate /Lens | Polycarbonate Transparent |
Case/Housing Material | FR-ABS Black |
Connectors /Terminal | Nylon 66, 33%GF, Black/Brass |
Mounting Clamps | Sturdy, Moulded Glass filled nylon with screws. |
Decimal Point | Auto Scrolling |
Dielectric Strength | 2.5KV @50 Hz 1 minute between Input -Auxiliary |
& Case - Terminals | |
Impulse Withstand | 3.5.KV, 1.2/50 micro Second |
Refresh Rate | Per 8.0ms |
Maximum Overload | Voltage 1.2 Times Continuous |
Frequency Response | 40-400 Hz |
Auxiliary Supply | 150-300V AC, 45-270V AC /DC, 19-60V AC /DC |
Input Voltage | 0- 750V AC(Direct) |
PT Primary Range | 50 to 500kV AC Programable |
PT Secondry Range | 50 to 500V AC Programable |
Accuracy Class | 1 & 0.5 (Freq. Measurement of Class 0.2) |
VA (Burden) | |
Auxiliary | ≤1.5 VA |
Voltage Input | ≤1.0 VA |
Environment | |
Calibration | 27⁰C ± 5⁰C |
Operating | 0⁰ to + 60⁰C, RH<70% |
Storage | -10⁰ to +70⁰C, RH<70% |
Metering Standard | IEC62052-11 |