Always Committed to delivering Excellence
Khasra No. 291, Gali No. 2, Shalimar Village Industrial Area, Delhi-110088 INDIA
Yokins Instruments Private Limited is the top DC VA Meter Manufacturers and trader renowned for their high-quality DC VA Meter instruments. A DC VA Meter, also known as a DC Volt-Ampere Meter, is a versatile measuring device used to measure both voltage (in volts) and current (in amperes) in a direct current (DC) circuit.
These Best DC Volt & Ampere Meter play a crucial role in various applications, including electronics, electrical engineering, and industrial processes. They allow engineers and technicians to accurately measure and monitor voltage and current values in DC circuits, enabling efficient troubleshooting and analysis.
Being the Top DC VA Meter Manufacturers in India, Yokins Instruments offers a wide range of LED Digital Display DC VA Meters equipped with advanced features such as easy-to-read displays, user-friendly interfaces, and precise measurement capabilities. Their meters are highly reliable, providing accurate readings even in challenging environments.
As the best Manufacturers of 100V-50A Dual Display Digital DC Volt-Amp Meter Module, whether you need to measure voltage and current in a small electronic circuit or a complex industrial setup, Yokins Instruments' DC Volt Amp Meter, LE-4020 are designed to meet your requirements. Trust their expertise and experience to deliver top-notch instruments for all your measuring needs.
Display | 4 Digit Red LED Super Bright Display |
Digit Height | 0.56"/14.2.mm |
Maximum display | 9999(Max) Counts |
Resolution | 0,001 to 1 Count Depending on Range/ Scale Display |
Display Stability | Within 1 Digit |
Faceplate /Lens | Polycarbonate Transparent |
Case/Housing Material | FR-ABS Black |
Connectors /Terminal | Nylon 66, 33%GF, Black/Brass |
Mounting Clamps | Sturdy, Moulded Glass filled nylon with screws. |
Decimal Point | Auto Scrolling |
Dielectric Strength | 2.5KV @50 Hz 1 minute between Input -Auxiliary & Case - Terminals |
Impulse Withstand | 3.5.KV, 1.2/50 micro Second |
Refresh Rate | Per8.0ms |
Maximum Overload | Voltage : 1.2 Times Continuous |
Current : 2 Times Continuous(mV) | |
Auxiliary Supply | 150-300V AC, 45-270V AC /DC, 19-60V AC /DC |
Input Current | 0-20A DIRECT , 0 - 75mV/0-60mV DC(SETTABLE) |
Input Voltage | 0- 800V DC(Direct) |
SCALE | KV RANGE VIA PROGRAMMING POSSIBLE. |
SHUNT | 1A-50kA PROGRAMABLE. |
Accuracy Class | 1 & 0.5 |
VA (Burden) | |
Auxiliary | ≤1.5 VA |
Current Input | ≤1.0 VA |
Voltage Input | ≤1.0 VA |
Environment | |
Calibration | 27⁰ C ± 5⁰C |
Operating | 0⁰ to + 60⁰C, RH<70% |
Storage | 10⁰ to +70⁰C, RH<70% |
Metering Standard | IEC62052-11 |