Always Committed to delivering Excellence
Khasra No. 291, Gali No. 2, Shalimar Village Industrial Area, Delhi-110088 INDIA
Three Phase LCD Multifunction Meter is an advanced electrical measuring device designed to monitor and display various parameters in a three-phase power system. It incorporates a digital LCD screen for clear and accurate readings.
The LCD display offers a user-friendly interface, making it easy to navigate through the different measurements and settings. Additionally, the Meter typically features various communication options, such as RS485 or Modbus, allowing for seamless integration with building management systems or other monitoring devices.
Yokins Instruments Private Limited takes immense pride in being recognized as one of the leading Exporters and dealers of Multifunction Meters 3 Phase. With an unwavering commitment to excellence, our state-of-the-art manufacturing facility ensures the production of high-quality, reliable, and accurate Meters.
Being the Top Three Phase Digital Energy Meter Exporters in India, Our Meters are intricately designed to meet the diverse needs of our esteemed customers. Equipped with advanced technology, these Digital 3 Phase Multifunction Meter offer precise measurements of various parameters such as voltage, current, power, energy, and more. The LCD display provides clear and easy-to-read information, making it convenient for users to monitor and analyse power consumption.
Choose Yokins Instruments Private Limited for top-notch 3-Phase Three Phase Multi-Function LCD Display that excel in performance, durability, and accuracy. Experience unmatched service and reliable products that will meet all your Metering needs.
RMS VoLtage | 20- 600Vrms (Accuracy - + 0.5% FS +1 dgt) |
RMS Current | 0020- 10.00Arms (Accuracy - 0.5% FS +1dt.) |
Active Power | 0.030- 6.000 KW (Accuracy i £ 05%ES +1dgt) |
Apparent Power | 0030+ 6.000 KVA (Accuracy - £05° ES +1 dgt) |
Reactive Power | 0030- 6.000 KVAF Accuracy - + 1.0% ES +1 dgt) |
Power Factor | 03 Lag-1.0- 0.3 Lead (Accuracy - £0.01 PE +1 dgt.) |
Line Frequency | 45.00-65.00 Hz (Accuracy: - 0.1Hz) |
Active Energy (KWh) | 000000.00- 999999.99 kwh (Accuracy Class 1,0.5) |
Apparent Energy (KVAh) | 000000.00- 999999.99 KVAh (Accuracy Class 1,0.5) |
Reactive Energy (KVArh) | 000000.00- 999999.99 KVATh (Accuracy Class 105) |
THO (V,I) | Indicative |
Faceplate /Lens | Polycarbonate Transparent |
Case/Housing Material | FR-ABS Black |
Connectors /Terminal | Nylon 66, 33%GF, Black/Brass |
Mounting Clamps | Sturdy, Moulded Glass filled nylon with screws. |
Decimal Point | Auto Scrolling |
Polarity Indication | L(Laggine/Inductive) or C(Leading/Capacitive) |
Under Range Indication | Error Code 01 Blinking when Current Non Detectable |
Dielectric Strength | 2.5KV @50 Hz 1 minute between Input -Auxiliary |
& Case - Terminals | |
Impulse Withstand | 3.5.KV, 1.2/50 micro Second |
Refresh Rate | Per 8.0ms |
Maximum Overload | Voltage 1.2 Times Continuous |
Current 2 Times Continuous | |
Auxiliary Supply | 150-300V AC, 45-270V AC /DC, 19- |
VA Burden (Typical) | |
Auxiliary | <2.5 VA |
Voltage Input | <0.2 VA / Phase |
Current Input | <0.2 VA / Phase |
PT Primary Range | 50 to 500kV AC Programable |
PT Secondary Range | 50 to 500V AC Programable |
CT Primary Range | 1A to 50kA AC Programable |
CT Secondary Range | 0.5A to 5A AC Programable |
Metering Standard | IEC 62053-21/22 |
Installation Category | Cat II (IEC / EN61010 - 1) |
Pollution | Degree 2 (IEC / EN61010 - 1) |
Environment | |
Calibration | 27°C ± 5°C |
Operating | 0° to 50°C, RH <70% |
Storage | 10° to 60°C, RH < 70% |
Dielectric Strength | 2.5 KV at 50 Hz for 1 mm |
Insulation Resistance | > 20 MOhms at 500 V DC |