Always Committed to delivering Excellence
Khasra No. 291, Gali No. 2, Shalimar Village Industrial Area, Delhi-110088 INDIA
Yokins Instruments Pvt. Ltd. DC Volt Amp meters are meant for measuring DC Voltage and DC Current simultaneously in a single meter, with 2 displays. We have wide Voltage and current ranges to offer and can also customize the same as per specific requirements, making them ideal for a variety of applications. They can be used in all applications where we have space constraint and want to use single meter instead of two separate meters for voltage and current measurement. Our meters are built with the highest quality components and are calibrated to meet or exceed industry standards, ensuring accurate and reliable readings every time. Our DC VA Meters are designed to be easy to use, with clear and concise displays and intuitive controls. Our DC VA meters are built to withstand the rigors of everyday use, with durable housings and impact-resistant displays. Our DC VA meters are competitively priced, offering excellent value for your money. We are so confident in the quality of our DC VAmeters that we offer a comprehensive warranty on all products.
Call us today to learn more about our DC Vameters and how they can benefit your business or organization.
VA meter
We offer a wide range of DC Digital Panel Meters to choose from. Contact us Today to learn more about our products and to find the best meter for your requirements.
Display | 4 Digit Red LED Super Bright Display |
Digit Height | 0.56"/14.2.mm |
Maximum display | 9999(Max) Counts |
Resolution | 0,001 to 1 Count Depending on Range/ Scale Display |
Display Stability | Within 1 Digit |
Faceplate /Lens | Polycarbonate Transparent |
Case/Housing Material | FR-ABS Black |
Connectors /Terminal | Nylon 66, 33%GF, Black/Brass |
Mounting Clamps | Sturdy, Moulded Glass filled nylon with screws. |
Decimal Point | Auto Scrolling |
Dielectric Strength | 2.5KV @50 Hz 1 minute between Input -Auxiliary & Case - Terminals |
Impulse Withstand | 3.5.KV, 1.2/50 micro Second |
Refresh Rate | Per8.0ms |
Maximum Overload | Voltage : 1.2 Times Continuous |
Current : 2 Times Continuous(mV) | |
Auxiliary Supply | 150-300V AC, 45-270V AC /DC, 19-60V AC /DC |
Input Current | 0-20A DIRECT , 0 - 75mV/0-60mV DC(SETTABLE) |
Input Voltage | 0- 800V DC(Direct) |
SCALE | KV RANGE VIA PROGRAMMING POSSIBLE. |
SHUNT | 1A-50kA PROGRAMABLE. |
Accuracy Class | 1 & 0.5 |
VA (Burden) | |
Auxiliary | ≤1.5 VA |
Current Input | ≤1.0 VA |
Voltage Input | ≤1.0 VA |
Environment | |
Calibration | 27⁰ C ± 5⁰C |
Operating | 0⁰ to + 60⁰C, RH<70% |
Storage | 10⁰ to +70⁰C, RH<70% |
Metering Standard | IEC62052-11 |
TERMINAL CONNECTION
MODEL | Y9-DVA |
FRONT | 96 X 96 |
DEPTH (Behind Bezel) | 39.5 |
Panel Cut -Out | 92 (+0.8-0.0) X 92(+0.8-0.0) |
MODEL | MEASURING RANGE | ACCURACY CLASS | AUX SUPPLY |
Y9-DVA | V A | 1 | 150-300V AC (TX Supply) |
0-10V DC 0-10A DC(DIRECT) | 0.5 | 45-270V AC /DC | |
0-20V DC 0-20A DC(DIRECT) | 19-60V AC /DC | ||
0-50V DC 0-75mV (SHUNT INPUT) | |||
0-100V DC 0-60mV(SHUNT INPUT) | |||
0-200 V DC -75-0-75 mV | |||
03-800V DC (SHUNT OR TRANSDUCER I/P) | |||
-60-0-60 mV | |||
(SHUNT OR TRANSDUCER I/P) |